Welcome to Shenzhen Jinxin Boerz Control Equipment Co., Ltd.!
简体中文
ENGLISH
Hotline: +86-755-89633862 / +86-13510015092
PRODUCTS

JXZ331 Self pressure regulating valve

JXZ331 Self pressure regulating valve

* with special taps, installation more simple and reliable 

* pressure setting point of a small range and mutual staggered, easy to use 

* rated Kv has a large capacity type, standard type, high precision three optional 

* self pressure regulating valve does not need additional energy, which is convenient and saves energy 

* pressure setting is convenient, running can be continuously without interference to set, maintenance free use 

*The pressure compensation device is designed to eliminate the influence of the pressure fluctuation on the set point precision, and the adjustment is more stable 

0.00
0.00
  
Product Description

* with special taps, installation more simple and reliable 

* pressure setting point of a small range and mutual staggered, easy to use 

* rated Kv has a large capacity type, standard type, high precision three optional 

* self pressure regulating valve does not need additional energy, which is convenient and saves energy 

* pressure setting is convenient, running can be continuously without interference to set, maintenance free use 

*The pressure compensation device is designed to eliminate the influence of the pressure fluctuation on the set point precision, and the adjustment is more stable 


Structure class

Self contained

structure type

Bellows balance type, double valve seat balance type, sleeve balance type

Spool type

Pressure balance type

Flow characteristics

Fast open, equal percentage, linear

pressure

1.6~32MPa, ANSI150~2500, 10K~63K

Size

DN20~500

Applicable temperature

-190~+450℃

Leak standard

IV、V、VI class

Connection type

Flange, thread, welding

actuator

Pneumatic diaphragm type, piston type

Product structure drawing


main parameters

 

 DN(mm)

20 

 25

 32

40 

 50

65 

80 

100 

 125

150 

200 

 Rated flow coefficient Kv

 Large capacity type

 11

20 

30 

48 

75 

 120

190 

300 

 480

 760

 Standard type

 7

 11

 20

 30

48 

75 

120 

 190

300 

480 

High Accurancy Type

2.8 

 11

 20

30 

48 

75 

120 

 190

300 

 Rated travelL(mm)

10 

14 

20 

25 

40 

50 

Pressure PN(Mpa)

             1.6  、4.0  、6.4  、10K  、16K  、20K  、ANSI150  、ANSI300                   

 Inherent flow characteristic

quick open

 Inherently adjustable ratioR

30 

Set point pressure adjustment range(Kpa)

15~50 40~80 60~100 80~140 120~180 160~220

200~260 240~300 280~350 330~400 380~450

430~500 480~560 540~620 600~700 680~800 780~900

880~1000 950~1500 1000~2500 2000~3000 2500~3500

 Adjustment precision(%)

Rubber diaphragm:±5   Piston type, metal diaphragm:±10 

 Maximum operating temperature(℃)

 -30~185  -30~350  250~560

Model


 Description

 JX331 Self pressure regulating valve



 Actuator 

 a

 diaphragm type

 b

 Piston type

 Size

 DN

 DN15-DN500

 upstream pressure

 Mpa

 xx Mpa

 downstream pressure

 Mpa

 xx Mpa

Material 

 1

 WCB

 2

 WC6

 3

 WC9

 4

 CF3

 5

 CF8

 6

 CF8M

 7

 CF3M

pressure

 PN

 PN10-PN64

working principle

Post valve pressure control

Working medium of the valve before the pressure P1 through the spool, after the throttle valve seat, into the valve after the pressure P2. P2 through the control line input to the actuator chamber under the effect of film in the top tray, the generated force and the spring reaction force equilibrium determines the relative position of the valve, the valve seat control valve pressure. When the valve after the pressure P2 increases, the force P2 acting on the top plate also increased. At this point, the top tray force greater than the spring reaction force, so that the valve is closed to the position of the valve seat, until the top plate of the force and the spring reaction force equilibrium. At this time, the flow area of the valve core and the valve seat is reduced, and the flow resistance becomes large, so that the P2 is reduced to a set value. Similarly, when the valve after the pressure P2 lower, the role of the direction and the opposite, which is self operated (after the valve) pressure regulating valve working principle.

 

Valve front pressure control

Working medium of the valve before the pressure P1 through the spool, after the throttle valve seat, into the valve after the pressure P2. While P1 through the control line input to the actuator effect on the membrane interior on the top tray, the generated force and the spring reaction force equilibrium determines the relative position of the valve, the valve seat, the control valve before the pressure. When the valve before the pressure P1 increases, the force P1 acting on the top plate also increased. At this point, the top tray force greater than the spring reaction force, the valve core to leave the seat to move in the direction of, until the top plate of the force and the spring reaction force balance so far. At this time, the valve core and the valve seat of the flow area increases, the flow resistance becomes small, so that the P1 down to the set value. Similarly, when the valve before the pressure P1 lower, the role of the direction and the opposite, which is self operated (valve front) pressure regulating valve working principle.

Working principle of self operated temperature control valve (heating)

Temperature control valve is based on the liquid can not be compressed and the principle of expansion and contraction. Heating with self operated temperature control valve, when the controlled object temperature is lower than the set temperature, temperature of liquid contraction, in the implementation of the push rod force decreases, components of the spool under the action of spring force opens the valve to increase the flow of steam and hot oil heating medium, the control object, the temperature rise, until the temperature of the controlled object to the set value, valve is closed, after the valve is closed, controlled object, the temperature drop, the valve open, heating medium and into the heat exchanger, and the temperature rise, so that the temperature of the controlled object to a constant value. The valve opening size is related to the difference between the actual temperature and the set temperature of the controlled object.

 

Working principle of self operated temperature control valve (cooling type)

Cooling with self operated temperature control valve works can refer to heating with self operated temperature control valve, only when the valve core component in the implementation of the device and the action of the spring force to open and close off the valve and the temperature contrast, the valve body through the cold medium, mainly used in cooling device of temperature control.